The widespread use of solenoid valves has led to increasing demands for their production in the industry. More and more attention is being paid to the selection of materials for electromagnetic valve bodies. In the selection of many elements, we will pay more attention to the corrosion resistance of valve body materials. Due to the complexity of anti-corrosion issues in solenoid valves. Under the influence of acidity, temperature, and humidity, the solenoid valve body is easily corroded. Not only is it a matter of data attributes, but we also consider a series of factors such as price, market, and supply when selecting. Therefore, the selection of valve bodies in the electromagnetic valve industry is a very knowledgeable question.
Solid substances are brought into the valve, causing the solenoid valve to fail to close properly. The vast majority of electromagnetic valves cannot have any particulate matter brought into the valve, even small particles are not allowed. A customer once sent a DN100 water valve back to the factory from afar, requesting help with repairs. After we opened the valve, we found a small iron filings on the diaphragm. When it is removed, the valve body and accessories are cleaned from the beginning, and then tested from the beginning, the valve can function normally. We have seen small stones, raw materials, iron filings, and even cockroaches in the valves we sent back for repair.
Many times, the outer surface of the valve body is also subject to atmospheric corrosion, and steel materials are generally protected by painting. At the same time, fabric measures such as lead lining, aluminum lining, engineering plastic lining, natural rubber lining, and various synthetic rubbers are often adopted for corrosion prevention of valve bodies. Again, in situations where pressure and temperature are not high, using non-metallic materials as the main body of the valve can often effectively prevent corrosion.
The corrosion of valve bodies can take two forms, namely chemical corrosion and electrochemical corrosion. Its corrosion rate is determined by the temperature, pressure, chemical function of the medium, and the anti-corrosion ability of the valve body material. So when selecting materials, electromagnetic valve manufacturers need to consider many factors comprehensively.
Insufficient voltage causes the solenoid valve to not open properly. Especially for relatively low voltages such as DC24V, DC12V, and AC24V, it is necessary to ensure that the fluctuation amplitude of the voltage is within plus or minus 10%. If the power supply voltage is less than 10% of the additional voltage, it may cause the solenoid valve to not open properly.
Article source: Jiangmen Pneumatic Equipment Manufacturer http://yubisaki.cn
05-16
Jiangmen hydraulic component manufacturer: displacement of hydraulic pump
It is estimated that many people are not very clear about the displacement and flow rate of hydraulic pumps. Benzhengyun Hydraulic Editor will analyze the displacement and flow rate of hydraulic pumps
04-06
Jiangmen Hydraulic Component Manufacturer: What are the specific characteristics of hydraulic filter cartridges
Hydraulic filter element is used to purify and treat unqualified turbine oil, especially those with excessive acidic substances in the oil. So what are its detailed features?Features:1. Use three-leve
02-15
Jiangmen Pneumatic Equipment Manufacturer: Working Principle of Diaphragm Electromagnetic Valve
Principle of diaphragm electromagnetic valve: When energized, the electromagnetic coil generates electromagnetic force, lifts the closing part from the valve seat, and opens the valve; When the power
01-10
Jiangmen Pneumatic Equipment Manufacturer: What are the advantages of pneumatic joint components
Pneumatic joints are the connecting points between pipelines, which can be disassembled and assembled between components and pipelines. It plays an indispensable role in pipe fittings and is one of th